Issue |
Int. J. Metrol. Qual. Eng.
Volume 8, 2017
|
|
---|---|---|
Article Number | 27 | |
Number of page(s) | 12 | |
DOI | https://doi.org/10.1051/ijmqe/2017022 | |
Published online | 17 November 2017 |
Research Article
The ITS-90 after definition of neon isotopic reference composition: extent of the isotopic effect tested on previous inter-comparison results
1
INTiBS,
Wroclaw, Poland
2
INRIM,
Torino, Italy
Received:
17
July
2017
Received in final form:
19
October
2017
Accepted:
20
October
2017
Starting from the end of the past century, the importance has been recognised of the effect of isotopic composition on some of the temperature fixed points for the most accurate realisations of the ITS-90. In the original definition of the latter, dating back to 1990, only a generic reference was made to “natural” composition of the substances used for the realisation of the fixed points, except for helium. The definition of a reference isotopic composition for three fixed points, e-H2, Ne and H2O, while eliminating the non-uniqueness of the Scale in this respect, induced detectable differences in the present and future realisations of the Scale, at the highest accuracy level, with respect to the previous realisations, when they affected the results of past MRA key comparisons, namely the CCT K1 (and K1.1) and CCT K2 (and K2.1–K2.5) and the related regional and supplementary ones. The paper provides evidence of the extent of this effect by using the results of the relevant key comparisons for neon archived in the BIPM KCDB, and of other comparisons existing in the literature (1979–1984, 2007–2012 and 2009–2010 sealed cell comparisons), and discusses the meaning and the outcomes of this evaluation.
Key words: isotopes / isotopic correction / chemical corrections / neon / triple point / intercomparisons / ITS-90
© F. Pavese et al., published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.