Open Access

Table 1

Relative sensitivity of optical distance measurements to the variation of environmental parameters: temperature ΔT, pressure Δp, partial pressure of water vapour Δpw and carbon dioxide content Δxc around T = 293 K, p = 1013.25 hPa, RH = 50% and xc = 450 ppm for an optical wavelength of 1550 nm. Values calculated using the equation of Bönsch and Potulski[2].

Parameter Contribution
ΔT ¯0.95 (μm/m)/K
Δp +0.27 (μm/m)/hPa
Δpw ¯0.09 μm/m for +10%
Δxc +0.03 μm/m for +200 ppm

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.