Open Access

Table 2

Uncertainty components evaluation utilized for the proposed approach.

Class Relative uncertainty of the force-proving instrument (%) Deadweights machine uncertainty (%)

Reproducibility Repeatability Interpolation zero Reversibility Creep Resolution
u1 u2 u3 u4 u5 u6 u7 u8
0 0.000289 0.000144 0.025 0.00012 0.000404 0.000144 0.007217 0.005
0,5 0.000578 0.000289 0.050 0.00025 0.000866 0.000289 0.014434 0.010
1 0.001155 0.000577 0.100 0.0005 0.001732 0.000577 0.028868 0.025
2 0.002309 0.001155 0.200 0.0010 0.002887 0.001155 0.057735 0.050

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.