Open Access
Issue
Int. J. Metrol. Qual. Eng.
Volume 7, Number 2, 2016
Article Number 201
Number of page(s) 12
DOI https://doi.org/10.1051/ijmqe/2016004
Published online 25 April 2016
  1. KIAG, Technical documents, KISTLER Instrumente AG (KIAG). Available at http://www.kistler.com [Google Scholar]
  2. V.E. Bean, Dynamic pressure metrology, Metrologia 30, 737–741 (1993) [CrossRef] [Google Scholar]
  3. J.P. Damion, Means of dynamic calibration for pressure transducers, Metrologia 30, 743–746 (1993) [CrossRef] [Google Scholar]
  4. J.L. Schweppe, L.C. Eichenberger, D.F. Muster, E.L. Michaels, G.F. Paskusz, Methods for the dynamic calibration of pressure transducers, NBS Monograph 67 (1963) [Google Scholar]
  5. ASME, A Guide for the dynamic calibration of pressure transducers, ANSI B88.1-1972, USA, 1995 [Google Scholar]
  6. ISA, A guide for the dynamic calibration of pressure transducers, ISA-37.1601-2002, USA, 2002 [Google Scholar]
  7. J. Winkler, Quality improvement in piezoelectric pressure measurements by applying advanced calibration methods, 4e International Symposium on Ballistic Measurement, Switzerland, September 25–29, 1989 [Google Scholar]
  8. J.P. Damion, Capteur de pression de référence pour l’étalonnage dynamique, 7e Congrès International de Métrologie, France, 1995 [Google Scholar]
  9. C. Cater, Calibration of piezoelectric sensors for combustion pressure analysis, KIAG, 2006 [Google Scholar]
  10. M. Kobusch, T. Bruns, E. Franke, Challenges in practical dynamic calibration, AMCTM, France, June 23–25, 2008 [Google Scholar]
  11. J. Lally, D. Cummiskey, Dynamic pressure calibration, PRS-TN-15-0205, PCB Piezotronics, 2005 [Google Scholar]
  12. C. Bartoli, M. F. Beug, T. Bruns, C. Elster, T. Esward, L. Klaus, A. Knott, M. Kobusch, S. Saxholm and C. Schlegel, Traceable dynamic measurement of mechanical quantities: objectives and first results of this european project, Int. J. Metrol. Qual. Eng. 3, 127–135 (2012) [CrossRef] [EDP Sciences] [Google Scholar]
  13. T. Bruns, E. Franke, M. Kobusch, Linking dynamic to static pressure by laser interferometry, Metrologia 50, 580–585 (2013) [CrossRef] [Google Scholar]
  14. Y. Zhang, J. Zu, H.Y. Zang, Dynamic calibration method of high-pressure transducer based on quasi-delta function excitation source, Measurement 45, 1981–1988 (2012) [CrossRef] [Google Scholar]
  15. Photron, FASTCAM SA-5 specifications. Available at http://www.photron.com [Google Scholar]
  16. C. Robbe, N. Nsiampa, A. Oukara, A. Papy, Quantification of the uncertainties of high-speed camera measurements, Int. J. Metrol. Qual. Eng. 5, (2014) [CrossRef] [EDP Sciences] [Google Scholar]
  17. NI, Technical documents of LabVIEW, National Instruments (NI). Available at http://www.ni.com/labview [Google Scholar]
  18. AFNOR, Norme AFNOR NF ENV 13005: Guide pour l’expression de l’incertitude de mesure, AFNOR, Août 1999 [Google Scholar]
  19. L. Elkarous, F. Coghe, M. Pirlot, J-C. Golinval, Experimental techniques for ballistic pressure measurements and recent development in means of calibration, J. Phys.: Conf. Ser. 459, 012048, 2013 [CrossRef] [Google Scholar]
  20. A.A. Juhasz, C.D. Bullock, D.H. Newhall, Calibration of ballistic pressure transducers, Measurement and Control 146, 123–127 (1991) [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.