Table 2

Amplitude and corner frequency changing to parameter alteration.

Characteristics Parameter −10% −5% 0 5% 10%
Amplitude (×10−5 V/rad/s) B 9.741 10.282 10.823 11.364 11.906
l 9.741 10.282 10.823 11.364 11.906
r 10.336 10.578 10.823 11.071 11.320
R 10.238 10.529 10.823 11.119 11.418
Corner frequency (Hz) B 4.85 5.41 6.00 6.59 7.23
l 6.00 6.00 6.00 6.00 6.00
r 6.00 6.00 6.00 6.00 6.00
R 6.00 6.00 6.00 6.00 6.00