Comparison between the previous CB and the new CB.
Item | Previous CB | New fabricated CB |
---|---|---|
No. of decades/box | 2 | 3 |
No. of microcontrollers/box | One microcontroller/decade | Only one for the whole box |
Type of the used capacitive components | Tantalum | Silvered mica and metallized polypropylene sulfide |
No. of capacitive elements/decade | 4 | 4 |
Nominal capacitance values | C, 2C, 3C and 4C | C, 2C, 4C and 8C |
No. of capacitance steps/decade | 10 | 15 |
Range | 100 nF to 10 μF | 100 nF to 150 μF |
Maximum setting value | 11 μF | 166.5 μF |
Maximum different output capacitance steps | 100 | 1666 |
Relative deviation of the output steps | ±2 × 10−4 to ±2 × 10−3 | ±5 × 10−5 to ±5 × 10−4 |
Measurements repeatability | About 27 ppm | About 1 ppm |
Maximum measuring voltage | 50 VAC | 75 VAC |
Temperature coefficient | 1000 ppm/°C | 10–25 ppm/°C |
Automatic calibrations | Can be used | Can be also used |